DocumentCode :
1665448
Title :
Strain Analysis of Pelvis After Iliac Bone Tumor Resection
Author :
Cheng Liming ; Jia Yongwei ; Yu Guangrong ; Yan, Yu ; Yang Zhiyong ; Lou Yongjian ; Ni Ming ; Chen Bo ; Ding Zuquan
Author_Institution :
Orthopedic Depart of Tongji Hosp., Tongji Univ., Shanghai
fYear :
2008
Firstpage :
1185
Lastpage :
1188
Abstract :
The purpose of this study is to analyze the pelvic strain behavior after iliac tumor type I resection. Six adult cadaveric specimens were tested. The iliac subtotal resection models were established according to Ennecking´s type I resection. The surficial strains of the defect pelvis and the intact pelvis were measured using 6 strain gauges attached to the key regions of pelvis including the site of lateral sacral mass, iliac arcuate line and the superior ramus of pubis. Axial loading from the proximal lumbar was applied by MTS load cell in the gradient of 0 N to 500 N in the double feet standing state. Much change of the strains was found of the pelvis after type I resection. Compared with the intact pelvis, the remarkable change of strain values was found on both side of the superior ramus of pubis, compressive strain altering to tensile strain. In addition, the average strain values on the normal sites of lateral sacral mass (-554.5plusmn251.2 muepsiv ) and iliac arcuate line(-1105.5plusmn352.7 muepsiv) under vertical load of 500 N were enlarged, which were 2.86 times and 3.77 time as much as the those in the corresponding sites of the intact pelvis. The differences of strain values on this two sites between the defect pelvis and the intact pelvis were statistically significant (p<0.05). Biomechanical model of iliac tumor type I resection were established. In the defect pelvis , strain values on the normal side of the sacrum and the ilium which conduct compressive stress are enlarged. Strain values are also enlarged in the region of pubic symphysis, which conducts tensile stress. Essential pelvic reconstruction must be introduced to recover the normal pelvic stress conduction. The strain gauge method is simple and efficient, which can be used extensively in pelvic biomechanical research.
Keywords :
biomechanics; bone; cancer; compressive strength; statistical analysis; strain gauges; tensile strength; tumours; Ennecking´s type I resection; MTS load cell; adult cadaveric specimen; axial loading; compressive strain; iliac bone tumor resection; iliac subtotal resection model; pelvic biomechanical research; pelvis strain analysis; proximal lumbar; pubis; superior ramus; tensile strain; Bones; Capacitive sensors; Electric resistance; Electric variables measurement; Electrical resistance measurement; Electronic equipment testing; Neoplasms; Pelvis; Strain measurement; Tensile strain;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
Conference_Location :
Shanghai
Print_ISBN :
978-1-4244-1747-6
Electronic_ISBN :
978-1-4244-1748-3
Type :
conf
DOI :
10.1109/ICBBE.2008.624
Filename :
4535504
Link To Document :
بازگشت