• DocumentCode
    1667366
  • Title

    Comparison of Drive Patterns for Single Current Source EIT in Computational Phantom

  • Author

    Xu, Canhua ; Dong, Xiuzhen ; Shi, Xuetao ; Fu, Feng ; Shuai, Wanjun ; Liu, Ruigang ; You, Fusheng

  • Author_Institution
    Dept. of Biomed. Eng., Fourth Mil. Med. Univ., Xi´´an
  • fYear
    2008
  • Firstpage
    1500
  • Lastpage
    1503
  • Abstract
    Electrical impedance tomography (EIT) estimated the electrical conductivity distribution within a body. Bipolar drive pattern appeared in most EIT studies that the current was injected with a single current source and sink. In the present study, we built a computational phantom and compared the quality of dynamic EIT image in terms of data quality, resolution and anti-noise performance associated with three different bipolar drive patterns: polar drive pattern, pseudo-polar drive pattern and adjacent drive pattern. The results demonstrated that the pseudo-polar drive pattern is optimal.
  • Keywords
    electric impedance imaging; medical image processing; phantoms; tomography; adjacent drive pattern; antinoise performance; bipolar drive pattern; computational phantom; data quality; dynamic EIT image quality; electrical conductivity distribution; electrical impedance tomography; image resolution; pseudopolar drive pattern; single current source EIT drive pattern; Biomedical imaging; Biomedical measurements; Conductivity; Current measurement; Drives; Electrodes; Image reconstruction; Imaging phantoms; Military computing; Tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4244-1747-6
  • Electronic_ISBN
    978-1-4244-1748-3
  • Type

    conf

  • DOI
    10.1109/ICBBE.2008.704
  • Filename
    4535584