Title :
Performance evaluation of a fluid temperature compensated single sensor constant temperature anemometer
Author :
Ferreira, Rômulo P C ; Freire, Raimundo C S ; Deep, Gurdip S.
Author_Institution :
CEFET-AL, Maceio, Brazil
fDate :
6/24/1905 12:00:00 AM
Abstract :
The performance of a hot wire anemometer configuration is affected by variation in the fluid temperature. The classical temperature compensation techniques in such anemometers employ two sensors. The performance of a temperature compensated hot wire anemometer configuration using a single sensor alternating between two operating temperatures for constant fluid velocity, is investigate under conditions of time varying fluid velocity. The measurement error introduced is dimensioned which can be practically eliminated using a low pass digital filter.
Keywords :
anemometers; compensation; digital filters; low-pass filters; measurement errors; constant temperature hot wire anemometer; electrical equivalence; fluid temperature compensation; low pass digital filter; measurement error; single sensor; thermoresistive sensor; Bridge circuits; Feedback circuits; Fluid flow measurement; Monitoring; Resistors; Switching circuits; Temperature sensors; Thermal sensors; Voltage; Wire;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2002. IMTC/2002. Proceedings of the 19th IEEE
Print_ISBN :
0-7803-7218-2
DOI :
10.1109/IMTC.2002.1007085