DocumentCode :
1669632
Title :
Power monitoring circuit using operational amplifiers
Author :
Rerkratn, Apinai ; Petchmaneelumka, Wandee ; Julsereewong, Prasit ; Riewruja, Vanchai
Author_Institution :
Fac. of Eng., King Mongkut´´s Inst. of Technol. Ladkrabang, Bangkok, Thailand
fYear :
2010
Firstpage :
1639
Lastpage :
1642
Abstract :
In this paper presents a power monitoring circuit for battery energy management system using operational amplifiers. The proposed scheme consists of a current sensing circuit with voltage output and an analog multiplier. The voltage output of current sensing circuit is directly proportional to load current. The multiplying result of the load current in the form of voltage signal and the load voltage becomes the load power in term of output voltage of analog multiplier. The configuration of the proposed power monitoring circuit is simple and economically attractive. Simulation and experimental results confirming the performance of the proposed circuit are agreed with the expected values.
Keywords :
battery management systems; energy management systems; operational amplifiers; power integrated circuits; analog multiplier; battery energy management system; current sensing circuit; operational amplifiers; power monitoring circuit; Batteries; Load modeling; Monitoring; Power measurement; Resistors; Sensors; Voltage measurement; analog multiplier; current sensing; power monitoring;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control Automation and Systems (ICCAS), 2010 International Conference on
Conference_Location :
Gyeonggi-do
Print_ISBN :
978-1-4244-7453-0
Electronic_ISBN :
978-89-93215-02-1
Type :
conf
Filename :
5669649
Link To Document :
بازگشت