• DocumentCode
    1670222
  • Title

    Impedance measurement by means of a high-stability multiphase DDS generator, with the three-voltage method

  • Author

    Callegaro, Luca ; Galzerano, Gianluca ; Svelto, Cesare

  • Author_Institution
    Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
  • Volume
    2
  • fYear
    2002
  • fDate
    6/24/1905 12:00:00 AM
  • Firstpage
    1183
  • Abstract
    The system the intercomparison of unlike impedances of IEN, based on the three-voltmeter method and four-terminal pair definition of the standards, has now been provided with a new direct-digital synthesis generator, having multiple outputs, isolation among the channels, and high amplitude and frequency stability. Experimental results in the new and old configuration are shown and compared.
  • Keywords
    direct digital synthesis; electric impedance measurement; four-terminal pair definition; high-stability multiphase DDS generator; impedance measurement; standards; three-voltmeter method; Bridge circuits; Current measurement; DC generators; Electric variables measurement; Frequency; Impedance measurement; Master-slave; Phase measurement; Stability; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2002. IMTC/2002. Proceedings of the 19th IEEE
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-7218-2
  • Type

    conf

  • DOI
    10.1109/IMTC.2002.1007125
  • Filename
    1007125