• DocumentCode
    1670772
  • Title

    Asynchronous operation of hydrogenerator calculation verification by tests on old hydrogenerator in power plant

  • Author

    Zebic, Z. ; Maljkovic, Z. ; Pavlica, M.

  • Author_Institution
    Dept. of Electr. Machines, Drives & Autom., Zagreb, Croatia
  • Volume
    3
  • fYear
    2004
  • Firstpage
    1121
  • Abstract
    The extended testing of hydrogenerator (rated 35 MVA) was made because the generators working age expired and it was going to be replaced with new one. This was the perfect opportunity to do some specific and not usual testing. The complicated testing plan was designed in order to enable recording as much relevant data as possible (electrical, electromechanical, mechanical). Therefore in some phases of testing, 29 to 44 quantities were measured simultaneously. Further, the results of measuring and simulation for asynchronous operation of synchronous generator are shown.
  • Keywords
    hydroelectric generators; hydroelectric power stations; machine testing; 35 MVA; asynchronous operation; hydrogenerator testing; power plant; synchronous generator; testing plan; Automatic testing; Circuit testing; Magnetic field measurement; Mathematical model; Power generation; Rotors; Saturation magnetization; Stators; Synchronous generators; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrotechnical Conference, 2004. MELECON 2004. Proceedings of the 12th IEEE Mediterranean
  • Print_ISBN
    0-7803-8271-4
  • Type

    conf

  • DOI
    10.1109/MELCON.2004.1348259
  • Filename
    1348259