• DocumentCode
    1672171
  • Title

    Experimental study of coaxial cable noise mechanism on ion chamber measurement line for PHWR

  • Author

    Lee, Kwang-Dae

  • Author_Institution
    Nucl. Power Lab., KEPCO Res. Inst., Daejeon, South Korea
  • fYear
    2010
  • Firstpage
    835
  • Lastpage
    838
  • Abstract
    In this paper, the coaxial cable noise generated by bending or mechanical stress has been studied to find out the root cause of PHWR(Pressurized Heavy Water Reactor) trips at low power. The coaxial cable causes triboelectric noise from bending or vibration, and piezoelectric noise from dielectric characteristics of cable insulator. From measured cable noise results in the laboratory test and plant site test, the coaxial cable noise is estimated as a main factor that causes unpredictable reactor trip.
  • Keywords
    acoustic noise; bending; cables (mechanical); ionisation chambers; reactors (electric); triboelectricity; vibrations; PHWR; bending; coaxial cable noise mechanism; ion chamber measurement line; mechanical stress; piezoelectric noise; pressurized heavy water reactor; triboelectric noise; vibration; Coaxial cables; Detectors; Inductors; Mechanical cables; Noise; Stress; Vibrations; coaxial cable; noise; piezoelectric; triboelectric;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Automation and Systems (ICCAS), 2010 International Conference on
  • Conference_Location
    Gyeonggi-do
  • Print_ISBN
    978-1-4244-7453-0
  • Electronic_ISBN
    978-89-93215-02-1
  • Type

    conf

  • Filename
    5669753