Development of partial discharge monitor for turbine generators
Author :
Tsurimoto, T. ; Itoh, K. ; Kaneda, Y. ; Sumida, A. ; Kuroki, S. ; Ohsawa, T. ; Tanaka, H.
Author_Institution :
Mitsubishi Electr. Corp., Hyogo, Japan
fDate :
6/21/1905 12:00:00 AM
Abstract :
A new partial discharge (PD) monitor has been developed. It continuously monitors the electrical condition of stator winding insulation of turbine generators in service. Various turbine generators, such as those having large PD activity and load dependent PD, were measured
Keywords :
insulation testing; machine insulation; machine testing; monitoring; partial discharge measurement; stators; turbogenerators; PD activity; electrical condition monitoring; load dependent PD; machine insulation testing; partial discharge monitor development; stator winding insulation; turbine generators; Coils; Condition monitoring; Electromagnetic interference; Frequency; Partial discharges; Signal detection; Stator cores; Stator windings; Turbines; Wires;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 1999. Proceedings
Conference_Location :
Cincinnati, OH