DocumentCode :
1676848
Title :
A Technique for Accurate Frequency Response Measurement of Integrated Continuous-Time Filters
Author :
Pavan, Shanthi ; Laxminidhi, Tonse
Author_Institution :
Dept. of Electr. Eng., Indian Inst. of Technol., Madras
fYear :
2006
Firstpage :
77
Lastpage :
80
Abstract :
We present a technique to accurately characterize the frequency response of high frequency on-chip continuous-time filters. When compared to conventional methods of measurement, the proposed technique shows two orders of magnitude improvement in accuracy. Experimental results are shown for a 75 MHz fifth order Chebyshev Gm-C ladder filter designed in a 0.35 mum CMOS process and packaged in a 40 pin dual-in-line package
Keywords :
CMOS integrated circuits; Chebyshev filters; continuous time filters; frequency measurement; frequency response; ladder filters; millimetre wave filters; 0.35 micron; 75 MHz; CMOS process; dual-in-line package; fifth order Chebyshev Gm-C ladder filter; frequency response measurement; integrated continuous-time filters; Active filters; Circuits; Electric variables measurement; Flow graphs; Frequency measurement; Frequency response; Packaging; Signal design; Testing; Transfer functions;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Custom Integrated Circuits Conference, 2006. CICC '06. IEEE
Conference_Location :
San Jose, CA
Print_ISBN :
1-4244-0075-9
Electronic_ISBN :
1-4244-0076-7
Type :
conf
DOI :
10.1109/CICC.2006.320980
Filename :
4114912