An assessment study of two different shunt FACTS devices for compensating disturbances due to voltage variation in power systems is presented in this paper. Namely, Static Compensator (STATCOM) and Static Var Compensator (SVC) are Considered in this study. Eigen Value analysis and nonlinear time domain simulations for starting motor, motor in load varying state and short circuit on motor terminals show that STATCOM DC Voltage regulation has a better performance Compared to that of SVC. The result that will be presented in the paper will prove the superiorly of STATCOM over SVC in increasing motor speeding up and improving system voltage profile particularly at starting.