DocumentCode :
1678711
Title :
Operation of high power cycloconverter-fed gearless drives under abnormal conditions
Author :
Pontt, J. ; Rodríguez, J. ; Tishcler, K. ; Becker, N. ; Rebolledo, J.
Author_Institution :
Dept. of Electron., Santa Maria Casilla Univ., Valparaiso, Chile
Volume :
2
fYear :
2004
Firstpage :
1083
Abstract :
This paper presents the behavior of large power mills (more than 10 MW each) fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions which can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage.
Keywords :
cycloconvertors; electric drives; electric field measurement; gears; grinding; milling; mineral processing industry; thyristor applications; abnormal condition; control failure; equipment damage; field measurement; high power cycloconverter-fed gearless drives; large power mill; power outage; protective design; reverse voltage; thyristor; Circuit faults; Current measurement; Electronic mail; Milling machines; Power system reliability; Production; Protection; Stators; Synchronous machines; Synchronous motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2004. 39th IAS Annual Meeting. Conference Record of the 2004 IEEE
ISSN :
0197-2618
Print_ISBN :
0-7803-8486-5
Type :
conf
DOI :
10.1109/IAS.2004.1348547
Filename :
1348547
Link To Document :
بازگشت