DocumentCode :
1679654
Title :
Discharge current from lift-up device
Author :
Soda, Yutaka
Author_Institution :
Dept. of Adv. Tape Storage Dev., Sony Corp., Yokohama, Japan
Volume :
2
fYear :
2004
Firstpage :
1302
Abstract :
A small sensor of a GMR head for magnetic recording is easily affected by electrostatic discharge (ESD). It was found that a small capacitance device could increase the high voltage and discharge with high peak current when the device is lifted up. It was also found that the GMR head could be designed to reduce ESD risk.
Keywords :
electrostatic discharge; giant magnetoresistance; magnetic recording; GMR; capacitance device; discharge current; electrostatic discharge; giant magnetoresistance; lift-up device; magnetic recording; Capacitance; Capacitors; Current measurement; Electrical resistance measurement; Electrostatic discharge; Fault location; Magnetic heads; Needles; Probes; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2004. 39th IAS Annual Meeting. Conference Record of the 2004 IEEE
ISSN :
0197-2618
Print_ISBN :
0-7803-8486-5
Type :
conf
DOI :
10.1109/IAS.2004.1348581
Filename :
1348581
Link To Document :
بازگشت