DocumentCode
167992
Title
Comparative analysis of power quality on bus-bars of the main switchboard and terminal of exemplary load at marine microgrid
Author
Pilat, Andrzej ; Tarasiuk, Tomasz
Author_Institution
Dept. of Marine Electr. Power Eng., Gdynia Maritime Univ., Gdynia, Poland
fYear
2014
fDate
16-18 Oct. 2014
Firstpage
764
Lastpage
768
Abstract
The paper´s aim is to analyze and discuss results of experimental investigation of power quality parameters at two points of exemplary ship power system. Namely, the bus-bars of the main switchboard and terminal of exemplary load (the electric motor of deck crane pump) have been considered. Particularly, measured voltage and frequency deviations are shown, completed by distortion analysis. The level of distortion and their propagation are presented.
Keywords
distortion; distributed power generation; marine power systems; power supply quality; pumps; bus bars; comparative analysis; deck crane pump; distortion analysis; electric motor; exemplary load; exemplary ship power system; frequency deviations; marine microgrid; power quality parameters; switchboard; voltage deviations; Distortion measurement; Frequency measurement; Marine vehicles; Power measurement; Power quality; Switches; Voltage measurement; marine electric power system; power quality;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Power Engineering (EPE), 2014 International Conference and Exposition on
Conference_Location
Iasi
Type
conf
DOI
10.1109/ICEPE.2014.6970013
Filename
6970013
Link To Document