DocumentCode
1682764
Title
Some problems of the active power enhancement of the high power arc furnaces
Author
Karpati, A. ; Karacs, I. ; Magyar, T.
Author_Institution
Tech. Univ. Budapest, Hungary
fYear
1999
Firstpage
172
Abstract
An often-used method for intensification of the high power arc furnaces is to increase the length of the arc. In this case it is usually necessary to change the furnace transformer and the electrode controller. Of course, due to the higher power, the conditions of the connection to the supply network are also investigated. The paper gives the analyses of the experiences gained at such an intensification process primarily focusing on the low frequency EMC problems. Measurement results are shown to illustrate the observed phenomena.
Keywords
arc furnaces; compensation; electromagnetic compatibility; power harmonic filters; power system harmonics; power transformers; reactive power; static VAr compensators; active power enhancement; arc length increase; electrode controller; furnace transformer; harmonic filters; high power arc furnaces; low frequency EMC problems; reactive power compensation; static VAr compensators; Circuits; Damping; Electrodes; Furnaces; Harmonic distortion; Harmonic filters; Inductors; Power harmonic filters; Static VAr compensators; Voltage fluctuations;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Power Engineering, 1999. PowerTech Budapest 99. International Conference on
Conference_Location
Budapest, Hungary
Print_ISBN
0-7803-5836-8
Type
conf
DOI
10.1109/PTC.1999.826604
Filename
826604