DocumentCode
1686667
Title
Lightweight, ironless-stator, PM generators for direct-drive wind turbines
Author
Spooner, E. ; Gordon, P. ; French, C.D.
Author_Institution
New & Renewable Energy Group, Durham Univ., UK
Volume
1
fYear
2004
Firstpage
29
Abstract
A new form of direct-drive PM generator for wind turbines is described. Despite being a very low speed machine, it is very light in weight because of its large diameter and the absence of iron in the stator magnetic circuit. Its efficiency is good and it offers the possibility of fault-tolerant operation and high-voltage output, eliminating the need for a unit transformer. A 2m diameter laboratory demonstrator is shown and initial measurements confirm design data.
Keywords
permanent magnet generators; stators; wind turbines; 2 m; direct-drive wind turbines; fault-tolerant operation; high-voltage output; lightweight ironless-stator PM generators; unit transformer;