DocumentCode :
1687966
Title :
Multi-sensor arm rehabilitation monitoring device
Author :
Ambar, Radzi Bin ; Poad, Hazwaj Bin Mhd ; Ali, Abdul Malik Bin Mohd ; Ahmad, Muhammad Shukri Bin ; Jamil, Muhammad Mahadi Bin Abdul
Author_Institution :
Dept. of Comput. Eng., Univ. Tun Hussein Onn Malaysia, Parit Raja, Malaysia
fYear :
2012
Firstpage :
424
Lastpage :
429
Abstract :
Rehabilitation activities require continuous monitoring process in order to provide information of rehabilitation results to be analyzed by physical therapist. The purpose of monitoring is to help them to improve rehabilitation process. Moreover, a portable and simple home-based rehabilitation device can help patients to improve daily rehabilitation activity. Some previous studies regarding home-based rehabilitation process have shown improvement in promoting human movement recovery. But existing rehabilitation devices are expensive and need to be supervised by physical therapist, which are complicated to be used at home. Some devices (such as exoskeleton-type devices) are also not so efficient to be used at home due to large size and complex system. In this current work combination of sensors (flex sensor, force sensitive sensor and accelerometer) were assessed in order to be implemented as a multi-sensor unit for a portable arm rehabilitation device. Analog signal from the sensors will be conveyed to an Arduino microcontroller for data processing and logging. The results of rehabilitation activity can be used for further monitoring and analysis. An LCD display will show to the user the achievement of their exercise activity.
Keywords :
accelerometers; biomechanics; biomedical electronics; force sensors; liquid crystal displays; patient monitoring; patient rehabilitation; portable instruments; Arduino microcontroller; LCD display; accelerometer; analog signal; data logging; data processing; exercise activity; flex sensor; force sensitive sensor; home-based rehabilitation device; human movement recovery; multisensor arm rehabilitation monitoring device; portable arm rehabilitation device; portable device; Accelerometers; Flexible printed circuits; Force; Force sensors; Immune system; Monitoring; arm rehabilitation; monitoring device; multi-sensor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering (ICoBE), 2012 International Conference on
Conference_Location :
Penang
Print_ISBN :
978-1-4577-1990-5
Type :
conf
DOI :
10.1109/ICoBE.2012.6179051
Filename :
6179051
Link To Document :
بازگشت