Title :
Interior point method for hydro-thermal optimal power flow
Author :
Wei, Hua ; Sasaki, Hiroshi ; Kubokawa, Junji
Author_Institution :
Dept. of Electr. Eng., Hiroshima Univ., Japan
Abstract :
This paper presents a new decoupling hydrothermal optimal power flow model and algorithm. Compared with Newton´s method, the proposed method can cut down the requirement of memory more than 100 times. Moreover, computational time can be reduced enormously with system scale and hence it is especially suitable for large scale power systems. Simulation results on test systems, the maximum system of which includes 37,228 primal-dual variables, have verified the robustness and speed of the proposed method
Keywords :
hydroelectric power stations; hydrothermal power systems; load flow; matrix algebra; optimisation; power system analysis computing; thermal power stations; algorithm; computer simulation; decoupling model; hydrothermal optimal power flow model; interior point method; large scale power systems; power plants; Character generation; Cost function; Fuels; Large-scale systems; Linear programming; Load flow; Optimization methods; Power generation; Power system modeling; Power system simulation;
Conference_Titel :
Energy Management and Power Delivery, 1995. Proceedings of EMPD '95., 1995 International Conference on
Print_ISBN :
0-7803-2981-3
DOI :
10.1109/EMPD.1995.500796