DocumentCode
169427
Title
Advanced FOUP purge using diffusers for FOUP door-off application
Author
Wang, H.P. ; Kim, Scott C. ; Liu, B.
Author_Institution
Entegris, Inc., Chaska, MN, USA
fYear
2014
fDate
19-21 May 2014
Firstpage
120
Lastpage
124
Abstract
In a number of key IC fabrication steps in-process wafers are sensitive to moisture, oxygen and other airborne molecular contaminants in the air. Nitrogen purge of closed Front Opening Unified Pods (FOUP) have been implemented in many fabs to minimize wafer´s exposure to the contaminants (or CDA purge if oxygen is not of concern). As the technology node advances, the need for minimizing the exposure has become even more stringent and in some processes requires FOUP purge while the FOUP door is off on an EFEM loadport. This requirement brings unique challenges to FOUP purge, especially at the front locations near FOUP opening, where EFEM air constantly tries to enter the FOUP. In this paper we present Entegris´ latest experimental study on understanding the unique challenges of FOUP door-off purge and the excellent test results of newly designed advanced FOUP with purge flow distribution manifolds (diffusers).
Keywords
clean rooms; integrated circuit manufacture; wafer level packaging; CDA purge; EFEM loadport; Entegris; FOUP door-off application; FOUP door-off purge; FOUP purge; IC fabrication; airborne molecular contaminants; closed front opening unified pods; nitrogen purge; purge flow distribution manifold; Fabrication; Humidity; Integrated circuits; Manifolds; Moisture; Nitrogen; Plugs;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Semiconductor Manufacturing Conference (ASMC), 2014 25th Annual SEMI
Conference_Location
Saratoga Springs, NY
Type
conf
DOI
10.1109/ASMC.2014.6846999
Filename
6846999
Link To Document