DocumentCode
1694848
Title
A new method to achieve real-time detection and tracking of network voltage phase angle jumping under grid faults
Author
Wang Zhi ; Liu XueJing ; Chen, Chen ; Wang Tong
Author_Institution
NARI Technol. Dev. Co., Ltd., Nanjing, China
Volume
1
fYear
2011
Firstpage
474
Lastpage
479
Abstract
Grid fault is a challenge for electrical equipments in operating and control stably. In order to enhance the reliable operation of network equipments, grid frequency, phase angle and amplitude tracking must be fast dynamic respond performance and high detection accuracy under various grid faults. So that the appropriate control measures can be taken timely. This paper presents a new method to achieve real-time detection and tracking of voltage phase angle jumping, at the same time extract positive and negative sequence instantaneous components, based on the existing phase detecting technique and the synchronous reference frame method. The principle of which is calculation by use of the present voltage or current components on d-q synchronous rotating coordinate system and the corresponding variables a sampling time before. So the method of acquiring the phase angle jumping value under grid faults has strong capacity, either can be used for instantaneous analyses of balanced faults or used for instantaneous analyses of unbalanced faults. In addition, it is important to promote operation control strategy for grid connected electrical equipments. As an example, it can be used in LVRT (Low Voltage Ride-Through) control for wind power development. The simulation results verify the advantages of the proposed method including: good real-time performance, suitable for the application of practical engineering, solving the problem of traditional symmetrical components only suitable for steady-state analyses of unbalanced faults and systems, without multiple complex calculations.
Keywords
power apparatus; power grids; power system control; power system faults; LVRT control; amplitude tracking; balanced fault instantaneous analyses; d-q synchronous rotating coordinate system; detection accuracy; dynamic respond performance; grid connected electrical equipment; grid fault; grid frequency; low voltage ride-through control; multiple complex calculation; negative sequence instantaneous component; network tracking; operation control strategy; phase detecting technique; real-time network detection; steady-state analyses; synchronous reference frame method; time extract positive; unbalanced fault instantaneous analyses; voltage phase angle jumping; wind power development; Automatic voltage control; Phase frequency detector; Power harmonic filters; Real time systems; Vectors; LVRT; grid faults; positive and negative sequence instantaneous components; real-time detection; voltage phase angle jumping;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Power System Automation and Protection (APAP), 2011 International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-9622-8
Type
conf
DOI
10.1109/APAP.2011.6180449
Filename
6180449
Link To Document