• DocumentCode
    1697376
  • Title

    Determination of defect size distributions based on electrical measurements at a novel harp test structure

  • Author

    Hess, Christopher ; Weiland, Larg H.

  • Author_Institution
    Inst. of Comput. Design, Karlsruhe Univ., Germany
  • fYear
    1997
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    To improve accuracy of electrically based measurements of defect densities and defect size distributions, we present a novel harp test structure. There, horizontal and vertical parallel lines will be placed inside a given boundary pad frame without using any additional active semiconductor devices. The enhanced 2D-permutation sequence provides that all neighborhood relationships of adjacent test structure lines are unique. This is the key to disentangle even multiple faults detected by fast digital measurements. For this reason, the number and size of individual defects will be extracted anywhere inside or in-between layers
  • Keywords
    circuit optimisation; fault diagnosis; inspection; integrated circuit testing; integrated circuit yield; production testing; 2D-permutation sequence; IC yield; adjacent test structure lines; boundary pad frame; defect densities; defect size distributions; electrical measurements; harp test structure; multiple faults; neighborhood relationships; parallel lines; Circuit faults; Circuit testing; Density measurement; Electric variables measurement; Electrical fault detection; Electrical resistance measurement; Materials testing; Semiconductor device measurement; Semiconductor devices; Size measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microelectronic Test Structures, 1997. ICMTS 1997. Proceedings. IEEE International Conference on
  • Conference_Location
    Monterey, CA
  • Print_ISBN
    0-7803-3243-1
  • Type

    conf

  • DOI
    10.1109/ICMTS.1997.589281
  • Filename