Title : 
The energy resolution of xenon-neon filled gas proportional-scintillation counters for X-rays below 2 keV
         
        
            Author : 
Borges, F.I.G.M. ; Santos, F.P. ; Dias, T.H.V.T. ; Rachinhas, P.J.B.M. ; Conde, C.A.N. ; Stauffer, A.D.
         
        
            Author_Institution : 
Dept. de Fisica, Coimbra Univ., Portugal
         
        
        
        
        
            Abstract : 
The energy spectra of X-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters (GPSC), exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this work, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe-Ne mixtures as detection media in this energy range. For a total pressure of I atmosphere, energy spectra were calculated for 9 mixtures with Xe concentrations varying from 10% to 100%. The results have shown that the addition of Ne to Xe significantly reduces distortion and improves the energy resolution of the full energy peaks.
         
        
            Keywords : 
Monte Carlo methods; X-ray spectra; gas scintillation detectors; proportional counters; 1 atm; 2 keV; Monte Carlo simulation; X-rays; Xe-Ne; Xe-Ne gas proportional-scintillation counters; energy resolution; energy spectra; Atmospheric measurements; Counting circuits; Distortion measurement; Energy measurement; Energy resolution; Loss measurement; Measurement standards; Pressure measurement; Radiation detectors; X-rays;
         
        
        
        
            Conference_Titel : 
Nuclear Science Symposium Conference Record, 2001 IEEE
         
        
        
            Print_ISBN : 
0-7803-7324-3
         
        
        
            DOI : 
10.1109/NSSMIC.2001.1008461