• DocumentCode
    1704853
  • Title

    Frequency domain identification of differential pressure cells

  • Author

    McGlone, Phtllip ; McGhee, Joseph ; Henderson, Ian A.

  • Author_Institution
    Ind. Control Centre, Strathclyde Univ., Glasgow, UK
  • fYear
    1999
  • fDate
    6/21/1905 12:00:00 AM
  • Firstpage
    42614
  • Lastpage
    42617
  • Abstract
    This paper outlines the identification of a pneumatic differential pressure cell using multifrequency binary sequence, or MBS, test signals. The d/p cell consists of a diaphragm, a pilot relay flapper/nozzle and a feedback bellows. The reported experimental results show that the cell has a first order linear response
  • Keywords
    pressure transducers; diaphragm; discrete Fourier transform; feedback bellows; first order linear response; frequency domain identification; multifrequency binary sequence test signals; octave extended signal; pilot relay flapper/nozzle; pneumatic differential pressure cell; pressure differences measurement; transfer function;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Innovative Pressure, Force and Flow Measurements (Ref. No. 1999/089), IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19990499
  • Filename
    828758