DocumentCode :
1705349
Title :
The appropriate dimensions of the porous micro-channel for blood ions separation
Author :
Seddigh, M. ; Abolfathi, N.
Author_Institution :
Dept. of Med. Eng., Amirkabir Univ., Tehran, Iran
fYear :
2013
Firstpage :
17
Lastpage :
21
Abstract :
Separation of nano-particles from the fluid in micro-channels has a wide application in industry and is the subject of a plenty of researches today. In the present paper, the flow of blood plasma which contains ions and is considered as nano-particles in a micro-channel has been studied. The channel inside wall is of a porous material which consists of amino functionalized group-type one that causes the ions to separate from the blood and absorb to the channel wall because of electrostatic interaction between blood ions and micro-channel wall material. Based on this study at first time, an optimum dimensions have been represented to decrease the process time and channel length.
Keywords :
blood; flow through porous media; haemodynamics; microchannel flow; nanomedicine; nanoparticles; porous materials; two-phase flow; blood ion separation; blood plasma flow; channel length; electrostatic interaction; microchannel wall material; nanoparticles; porous material; porous microchannel; Absorption; Blood; Educational institutions; Equations; Fluids; Ions; Mathematical model; Blood ions; Micro-channel; Porous channel; Separation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering (ICBME), 2013 20th Iranian Conference on
Conference_Location :
Tehran
Type :
conf
DOI :
10.1109/ICBME.2013.6782185
Filename :
6782185
Link To Document :
بازگشت