Title :
Real-time PET image reconstruction based on regularized pseudo-inverse of the system matrix
Author :
Selivanov, Vitali V. ; Lepage, Martin D. ; Lecomte, Roger
Author_Institution :
Metabolic & Functional Imaging Center, Sherbrooke Univ., Que., Canada
Abstract :
The feasibility of tomographic image reconstruction by projection data filtering based on the singular value decomposition of the system matrix has recently been demonstrated in high-resolution animal positron emission tomography (PET). A regularization methodology involving truncation of the singular value spectrum based on the systematic spatial resolution analysis has been proposed and successfully applied. In the present paper, we show how realtime image reconstruction can be achieved using the regularized pseudo-inverse of the system matrix. An update of the current image estimate can be obtained using one column of the regularized pseudo-inverse matrix to account for the next registered event, thus allowing, in principle, for instant visualization of the radioactivity distribution while the object is still being scanned. Computed estimates converge to the minimum-norm least-squares solution of the regularized inverse problem when sufficient total counts are acquired to fulfill the assumption of the normal data error distribution. The computing expenses for image updating to account for the next registered event depend only on the total number of pixels in the discrete image representation. Data storage requirements are discussed. Limited angle tomography and non-traditional detection geometry may be handled using the described image reconstruction approach as well. The proposed method was tested with the list-mode PET data.
Keywords :
image reconstruction; medical image processing; positron emission tomography; singular value decomposition; discrete image representation; high-resolution animal positron emission tomography; image reconstruction approach; limited angle tomography; list-mode PET data; minimum-norm least-squares solution; normal data error distribution; projection data filtering; radioactivity distribution; real-time PET image reconstruction; real-time image reconstruction; regularization methodology; regularized pseudo-inverse; regularized pseudo-inverse matrix; singular value decomposition; singular value spectrum; systematic spatial resolution analysis; tomographic image reconstruction; Animals; Data visualization; Distributed computing; Filtering; Image reconstruction; Matrix decomposition; Positron emission tomography; Real time systems; Singular value decomposition; Spatial resolution;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2001 IEEE
Print_ISBN :
0-7803-7324-3
DOI :
10.1109/NSSMIC.2001.1008678