• DocumentCode
    1707774
  • Title

    SPECT-CT system for small animal imaging

  • Author

    Weisenberger, A.G. ; Wojcik, R. ; Bradley, E.L. ; Brewer, P. ; Majewski, S. ; Qian, J. ; Ranck, A. ; Saha, M.S. ; Smith, K. ; Smith, M.F. ; Welsh, R.E.

  • Author_Institution
    Detector Group, Jefferson Lab., Newport News, VA, USA
  • Volume
    3
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1840
  • Lastpage
    1844
  • Abstract
    The detector group at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) and the Biology, Physics and Applied Sciences Departments at the College of William and Mary are collaborating on the development of a miniature dual modality SPECT-CT system for mouse imaging. The detector heads of the SPECT subsystem are capable of imaging the gamma- and X-ray emissions (28-35 keV) of the radioactive isotope iodine-125 (Ie 125). Two different sets of I-125 imaging detectors are configured on a gantry that has an open-barrel type design. One set of detector heads is based on the 1 inch square Hamamatsu R5900-M64 position sensitive photomultiplier tube coupled to crystal scintillator arrays. The other detector heads configured on the gantry are two 5-inch diameter Hamamatsu R3292-based compact gamma cameras. The X-ray radiographic projections will be obtained using a LIXI Inc. model LF-85-503-OS X-ray imaging system that has an active area of 5.5 cm in diameter. The open-barrel shaped gantry facilitates the positioning of various mini gamma-ray imaging detectors and the X-ray system. The data acquisition and gantry control is interfaced through a Macintosh G3 workstation. SPECT reconstruction results using the R5900 based detector are presented
  • Keywords
    calibration; computerised tomography; image reconstruction; medical image processing; single photon emission computed tomography; veterinary medicine; 28 to 35 keV; 5 inch; 5.5 cm; 125I imaging detectors; I; SPECT reconstruction; SPECT subsystem; X-ray emissions; X-ray imaging system; X-ray radiographic projections; compact gamma cameras; crystal scintillator arrays; detector heads; gamma-emissions; gantry; mini gamma-ray imaging detectors; miniature dual modality SPECT-CT system; mouse imaging; open-barrel type design; position sensitive photomultiplier tube; radioactive isotope 125I; small animal imaging; Animals; Biology; Gamma ray detection; Gamma ray detectors; Head; Optical imaging; Physics; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1008700
  • Filename
    1008700