DocumentCode
170838
Title
Enhancement in CMOS chip performance through microfluidic cooling
Author
Zhimin Wan ; Wen Yueh ; Joshi, Yash ; Mukhopadhyay, Saibal
Author_Institution
Georgia Inst. of Technol., Atlanta, GA, USA
fYear
2014
fDate
24-26 Sept. 2014
Firstpage
1
Lastpage
5
Abstract
High on-chip temperature can degrade chip performance, and increase high leakage power which contributes to a significant part of the total chip power consumption. Microfluidic cooling is believed to have better cooling ability than air cooling. However, very few experimental demonstrations of CMOS chips with integrated microfluidic cooling exist. This paper presents experimental results of a working CMOS chip capable of generating controllable heat and on-chip temperature sensing under air cooling and microfluidic cooling. Under natural air cooling, the leakage current increases exponentially by 1.9 X as the temperature increases from 26.3 °C to 57.6 °C. 18.8 °C temperature drop and 66.2% leakage current saving is achieved by microfluidic cooling compared to natural air cooling at heatflux 34.5 W/cm2. In addition, the time to reach a steady state in response to a sudden application of microfluidic cooling is only 48.5% of that of forced air cooling. Lastly, increasing the flow rate of microfluidic cooling does not decrease the temperature and leakage current much.
Keywords
CMOS integrated circuits; cooling; microfluidics; temperature sensors; CMOS chip performance; air cooling; controllable heat; flow rate; leakage current saving; microfluidic cooling; on-chip temperature sensing; temperature drop; Cooling; Heating; Leakage currents; Microfluidics; Temperature measurement; Temperature sensors; Thermal resistance;
fLanguage
English
Publisher
ieee
Conference_Titel
Thermal Investigations of ICs and Systems (THERMINIC), 2014 20th International Workshop on
Conference_Location
London
Type
conf
DOI
10.1109/THERMINIC.2014.6972541
Filename
6972541
Link To Document