DocumentCode
1710296
Title
A good practice guide for the use of GTEM cells in EMC measurements according to IEC61000-4-20
Author
Bozec, D. ; McCormack, L.M. ; Marvin, A.C. ; Nothofer, A. ; Alexander, M.J.
Author_Institution
York EMC Services Ltd., York Univ., UK
Volume
2
fYear
2004
Firstpage
660
Abstract
The standard IEC 610004-20 includes the GTEM cell as a measurement facility for EMC emission and immunity testing. Frequencies above 1 GHz are increasingly required for EMC measurements. This paper describes measurements performed to investigate the upper frequency limits for the use of GTEM cells, and presents some results of the research to produce a measurement good practice guide, giving guidance on how to perform EMC measurements according to IEC 61000-4-20, with acceptable uncertainties.
Keywords
IEC standards; TEM cells; electromagnetic compatibility; immunity testing; measurement uncertainty; EMC measurements; GTEM cells; IEC 610004-20; emission testing; good practice guide; immunity testing; uncertainties; Area measurement; Battery charge measurement; Calibration; Electromagnetic compatibility; Frequency measurement; IEC standards; Immunity testing; Performance evaluation; Size measurement; TEM cells;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2004. EMC 2004. 2004 InternationalSymposium on
Print_ISBN
0-7803-8443-1
Type
conf
DOI
10.1109/ISEMC.2004.1349878
Filename
1349878
Link To Document