DocumentCode
1710945
Title
Dielectric spectroscopy of multistress aged XLPE-cable insulation for examination of synergic effects
Author
Reuter, M. ; Gockenbach, E. ; Borsi, H.
Author_Institution
Div. of High Voltage Eng., Hannover Univ., Germany
Volume
1
fYear
2005
Firstpage
277
Abstract
In this paper dielectric spectroscopy investigation of multistress aged full-sized model cables with cross-linked polyethylene insulation in time and frequency domain are reported. The results expound those frequency domain measurements of the capacitance and the dissipation factor exhibit distinctive synergism in case of threshold exceeding aging parameters. Moreover the evaluation of time domain experiments recording the isothermal depolarisation current can clarify interaction between the factors of influence further to a certain extent.
Keywords
XLPE insulation; capacitance measurement; frequency-domain analysis; power cable insulation; spectroscopy; time-domain analysis; cable insulation; capacitance measurements; cross-linked polyethylene insulation; dielectric spectroscopy; dissipation factor; frequency domain; isothermal depolarisation current; multistress aged XLPE; synergic effects; time domain; Aging; Cable insulation; Capacitance measurement; Dielectric measurements; Dielectrics and electrical insulation; Electrochemical impedance spectroscopy; Frequency domain analysis; Frequency measurement; Isothermal processes; Polyethylene;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 2005. (ISEIM 2005). Proceedings of 2005 International Symposium on
Conference_Location
Kitakyushu
Print_ISBN
4-88686-063-X
Type
conf
DOI
10.1109/ISEIM.2005.193398
Filename
1496120