• DocumentCode
    1713058
  • Title

    The design of Rogowski coil with wide band using for partial discharge measurements

  • Author

    Zhu, J. ; Yang, L. ; Jia, J. ; Zhang, Q.

  • Author_Institution
    Sch. of Electr. Eng., Xi´´an Jiaotong Univ., China
  • Volume
    2
  • fYear
    2005
  • Firstpage
    518
  • Abstract
    The elaborated Rogowski coil with improved frequency characteristics is applied to measure partial discharge (PD) in XLPE cable. By selecting magnetic cores and optimizing chief parameters, the Rogowski coil has both wide bandwidth and high sensitivity. The coil was placed at the grounded wire of a 10 kV XLPE cable for measuring PD current. The cable was designed with an artificial defect of needlepoint pricked from the sheath. The results show that PD signals in XLPE cable can be detected by this coil with no distortion, and the real PD characteristics of needlepoint defect can be obtained from the PD signal.
  • Keywords
    XLPE insulation; coils; electric current measurement; insulation testing; magnetic cores; optimisation; partial discharge measurement; power cable insulation; power cable testing; 10 kV; PD current measurement; Rogowski coil design; XLPE cable; frequency characteristics; magnetic cores; needlepoint defects; optimization; partial discharge measurements; Bandwidth; Cable shielding; Coils; Distortion measurement; Frequency measurement; Magnetic cores; Partial discharge measurement; Partial discharges; Wideband; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 2005. (ISEIM 2005). Proceedings of 2005 International Symposium on
  • Print_ISBN
    4-88686-063-X
  • Type

    conf

  • DOI
    10.1109/ISEIM.2005.193603
  • Filename
    1496203