DocumentCode :
1713058
Title :
The design of Rogowski coil with wide band using for partial discharge measurements
Author :
Zhu, J. ; Yang, L. ; Jia, J. ; Zhang, Q.
Author_Institution :
Sch. of Electr. Eng., Xi´´an Jiaotong Univ., China
Volume :
2
fYear :
2005
Firstpage :
518
Abstract :
The elaborated Rogowski coil with improved frequency characteristics is applied to measure partial discharge (PD) in XLPE cable. By selecting magnetic cores and optimizing chief parameters, the Rogowski coil has both wide bandwidth and high sensitivity. The coil was placed at the grounded wire of a 10 kV XLPE cable for measuring PD current. The cable was designed with an artificial defect of needlepoint pricked from the sheath. The results show that PD signals in XLPE cable can be detected by this coil with no distortion, and the real PD characteristics of needlepoint defect can be obtained from the PD signal.
Keywords :
XLPE insulation; coils; electric current measurement; insulation testing; magnetic cores; optimisation; partial discharge measurement; power cable insulation; power cable testing; 10 kV; PD current measurement; Rogowski coil design; XLPE cable; frequency characteristics; magnetic cores; needlepoint defects; optimization; partial discharge measurements; Bandwidth; Cable shielding; Coils; Distortion measurement; Frequency measurement; Magnetic cores; Partial discharge measurement; Partial discharges; Wideband; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulating Materials, 2005. (ISEIM 2005). Proceedings of 2005 International Symposium on
Print_ISBN :
4-88686-063-X
Type :
conf
DOI :
10.1109/ISEIM.2005.193603
Filename :
1496203
Link To Document :
بازگشت