• DocumentCode
    1713883
  • Title

    IEC 5000h multi-stress test on polymeric insulators

  • Author

    Yamamoto, H. ; Zhu, Y. ; Otsubo, M. ; Honda, C. ; Takenouchi, O. ; Hashimoto, Y. ; Ohno, A.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Miyazaki Univ., Japan
  • Volume
    3
  • fYear
    2005
  • Firstpage
    580
  • Abstract
    To clarify the electrical characteristics and ageing mechanism of polymeric insulators, a novel separation method of leakage current using differential technique has been proposed and applied in the accelerated 5000-hour ageing test of Electricite de France (EdF´s test), which is a multi-stress environmental test to evaluate degradation degree of polymer insulators according as the IEC61109 ANNEX C standard. In this study, the relation between the accumulative charge of corona and dry band arc discharge and the degradation process of polymeric insulators was investigated.
  • Keywords
    arcs (electric); corona; differential equations; insulator testing; leakage currents; polymer insulators; IEC 5000h multistress environmental test; IEC61109 ANNEX C standard; ageing mechanism; corona; degradation process; differential technique; dry band arc discharge; leakage current; polymeric insulators; separation method; Accelerated aging; Dielectrics and electrical insulation; Electric variables; IEC standards; Insulator testing; Leakage current; Life estimation; Plastic insulation; Polymers; Thermal degradation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 2005. (ISEIM 2005). Proceedings of 2005 International Symposium on
  • Print_ISBN
    4-88686-063-X
  • Type

    conf

  • DOI
    10.1109/ISEIM.2005.193435
  • Filename
    1496239