Abstract
The noise voltage in the reference or ground of a printed circuit board is often the cause of unwanted radiated emission. Power supply planes attribute to the noise voltage. By replacing the power supply planes by tracks, the noise voltage in the reference or ground can be considerably reduced, which leads to a dramatic reduction of the radiated electromagnetic fields. This has been shown using transmission line equations for a general two-conductor line. Simulation and measurements results confirm the beneficial effect of removing power planes. A reduction of 50 dB in radiated electromagnetic field strength was obtained.
Keywords
circuit simulation; electromagnetic fields; electromagnetic interference; field strength measurement; printed circuit layout; transmission line theory; electromagnetic field strength; noise voltage reduction; power planes; power supply tracks; printed circuit board; radiated electromagnetic fields; simulation; transmission line equations; two-conductor line; unwanted radiated emission; Circuit noise; Electromagnetic fields; Electromagnetic interference; Equations; Noise reduction; Power measurement; Power supplies; Power transmission lines; Printed circuits; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2004. EMC 2004. 2004 InternationalSymposium on
Print_ISBN
0-7803-8443-1
Type
conf
DOI
10.1109/ISEMC.2004.1350030
Filename
1350030
Link To Document