    Configuration, operation and management of existing distribution networks are based on passive networks, whereby the role of such networks is confined to transferring electricity from generation and transmission system to load centres. Under this situation, the main function of distribution network is delivering good quality electricity with minimum amount of network control to the load centres at different voltage level regardless of the most critical case. Most distribution networks are designed to operate in radial mode without having generation unit accommodate on them. Continued increase of distributed generation (DG) penetration into existing distribution networks in recent years has resulted in bi-directional power flow and changes in network voltage profile. These in turn caused important impact on the operation of conventional feeder protection schemes that are originally designed based on radial network operation assumption. The protection issues that had been identified in the presence of DG include (i) malfunction of protective devices due to increase of network fault current level, (ii) unnecessary tripping of non- directional relays due to significant fault contribution by DG, (iii) reduction of fault detection sensitivity of overcurrent relays due to fault contribution of DG, (iv) fault clearing time of graded overcurrent relays is affected and (v) operation of re-closer is affected with introduction of LOM relay. It has been reported that future distribution networks are likely to be operated in ring mode rather than radial in order to optimise the integrated capacity of DG. There are advantages in adopting ring mode operation but it could complicate the protection systems of networks with integrated DG. This paper reports an investigation into the impact of distributed generation on the setting of protective devices of distribution networks that originally operated in radial mode and then switched to ring mode and to compare the protection requireme- nts for the two modes of operations.
  • Keywords
    distributed power generation; fault location; load flow; power distribution faults; power distribution protection; relay protection; active distribution networks; bidirectional power flow; distributed generation penetration; fault contribution; fault detection; good quality electricity; network fault current level; network voltage profile; nondirectional relays; overcurrent relays; passive networks; protection requirements; protective devices; radial network operation; unnecessary tripping; Bidirectional control; Distributed control; Energy management; Fault diagnosis; Load flow; Passive networks; Power generation; Protection; Protective relaying; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Tech, 2007 IEEE Lausanne
  • Conference_Location
    Lausanne
  • Print_ISBN
    978-1-4244-2189-3
  • Electronic_ISBN
    978-1-4244-2190-9
  • Type

    conf

  • DOI
    10.1109/PCT.2007.4538483
  • Filename
    4538483