• DocumentCode
    1716476
  • Title

    Survey and analysis of chloride-induced corrosion on hydraulic concrete in the east of zhejiang

  • Author

    Zhou Jian-fen ; Chen Bin ; Guo Xue-mang ; Zhang Jing-zhi

  • Author_Institution
    Zhejiang Water Conservancy & Hydropower Coll., Hangzhou, China
  • Volume
    3
  • fYear
    2011
  • Firstpage
    2015
  • Lastpage
    2017
  • Abstract
    The aging of hydraulic concrete construction has been surveyed in the east of Zhejiang. The chloride-induced corrosion on the concrete surface was counted and analyzed. The relationships of 28 days concrete strength, water-cement ratio, admixture, sand ratio and the 28 days electric flux ratio are compared by the Compos System. The influence of the chloride ion diffusion is studied under changing of mix proportion. It has be found that the inadequacy of concrete cover ply is quite common and leading to severe reduction for structural durability.
  • Keywords
    concrete; corrosion; durability; hydraulic systems; structural engineering; Compos System; Zhejiang; admixture; chloride ion diffusion; chloride-induced corrosion; concrete cover ply; concrete strength; concrete surface; electric flux ratio; hydraulic concrete construction; sand ratio; structural durability; water-cement ratio; Concrete; chloride ions diffusion; durability; hydraulic concrete; mix proportion; survey;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Water Resource and Environmental Protection (ISWREP), 2011 International Symposium on
  • Conference_Location
    Xi´an
  • Print_ISBN
    978-1-61284-339-1
  • Type

    conf

  • DOI
    10.1109/ISWREP.2011.5893655
  • Filename
    5893655