Title : 
A Method for Optimally Localizing Power Quality Monitoring Devices in Power Systems
         
        
            Author : 
Dzienis, C. ; Komarnicki, P. ; Styczynski, Z.A.
         
        
            Author_Institution : 
Otto von Guericke Univ., Magdeburg
         
        
        
        
        
            Abstract : 
This paper presents a method for optimally localizing power quality monitoring devices in power systems. The method is based on calculating the load flow in the frequency domain. The computation algorithm also obtains the Jacobi matrix that reflects the working point of a power system. Singular value decomposition enables obtaining information about nodes sensitive to harmonic. These nodes are where the power quality monitoring systems should be installed.
         
        
            Keywords : 
Jacobian matrices; frequency-domain analysis; load flow; power apparatus; power supply quality; power system measurement; Jacobi matrix; load flow; optimally power quality monitoring devices; singular value decomposition; Harmonic analysis; Iterative algorithms; Jacobian matrices; Load flow; Monitoring; Power measurement; Power quality; Power system harmonics; Power system modeling; Power systems; Harmonic Load Flow; Modeling; Power Quality Monitoring System; Singular Value Decomposition;
         
        
        
        
            Conference_Titel : 
Power Tech, 2007 IEEE Lausanne
         
        
            Conference_Location : 
Lausanne
         
        
            Print_ISBN : 
978-1-4244-2189-3
         
        
            Electronic_ISBN : 
978-1-4244-2190-9
         
        
        
            DOI : 
10.1109/PCT.2007.4538541