• DocumentCode
    1717747
  • Title

    Optimal design in PET data acquisition: a new approach using simulated annealing and component-wise Metropolis updating

  • Author

    Liao, W.-H. ; Lange, K. ; Huang, S.-C. ; Bergsneider, M.

  • Author_Institution
    Sch. of Med., California Univ., Los Angeles, CA, USA
  • Volume
    4
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1979
  • Lastpage
    1983
  • Abstract
    Dynamic positron emission tomography is a powerful tool of measuring biological activities in vivo. Due to the inherent high noise level, there are always concerns about how to increase the signal to noise ratio. One possible approach is to optimize the experimental design. In this study we propose a discretized representation of the experimental design problem and transform it to a combinatorial problem. This combinatorial optimization problem then can be solved using simulated annealing with Component-wise Metropolis Monte Carlo simulation. We showed that using this novel approach one can deal with the problem of designing an optimal input function and an optimal sampling schedule efficiently. Our results show that the current dynamic scanning of approximate twenty frames doesn´t give us much more information than an optimized four-frame schedule, and needlessly increases storage requirements. This is consistent with the conclusion given by Li et al. We also reproduced the optimal sampling schedule for FDG study. Moreover, we show that the single bolus ejection is almost optimal in the sense of D-optimal design as well as many other measures
  • Keywords
    Monte Carlo methods; combinatorial mathematics; data acquisition; optimisation; positron emission tomography; simulated annealing; Monte Carlo simulation; biological activities; combinatorial problem; component-wise Metropolis updating; discretized representation; dynamic PET data acquisition; dynamic scanning; optimal design; optimal input function; optimal sampling schedule; positron emission tomography; signal to noise ratio; simulated annealing; single bolus ejection; Data acquisition; Design for experiments; Design optimization; Dynamic scheduling; In vivo; Noise level; Positron emission tomography; Sampling methods; Signal to noise ratio; Simulated annealing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009212
  • Filename
    1009212