    Observer studies of cardiac lesion detectability with triple-head 360° vs. dual-head 180° SPECT acquisition using simulated projection data

  • Author

    Chen, Mu ; Peter, Jöerg ; Jaszczak, Ronald J. ; Gilland, David R. ; Bowsher, James E. ; Tornai, Martin P. ; Metzler, Scott D.

  • Author_Institution
    Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
  • Volume
    4
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    2229
  • Lastpage
    2233
  • Abstract
    The purpose of this study is to evaluate cardiac lesion detectability with triple-head 360-degree versus dual-head 180-degree myocardial perfusion SPECT scans with equal acquisition time. The channelized Hotelling observer (CHO) and human observers were used. A male and a female voxelized four-dimensional cardiac-torso phantoms were used to generate the 360-degree and the 180-degree projection data. A cold lesion was placed in 8 different locations of myocardium and had a lesion contrast of 25%. Sufficient poisson noise was added to set the area under the ROC curve (Az) to be between 0.75 to 0.85 in a pilot study, and to simulate the clinical case where dual-head 180-degree and triple-head 360-degree both have the same total scan time. For each lesion location, 100 realizations of lesion present and of lesion-absent data were generated. Five iteration OSEM was used to reconstruct the data with no attenuation correction. A 3D Hann filter with 0.7 times the Nyquist frequency was used to smooth the reconstructed images. The CHO showed a higher lesion detectability index d´ for the 180-degree data. The human observer study showed a slightly better detection performance of the 180-degree scan, especially for the female phantom, but the differences were not statistically significant (at the P = 0.05 level)
  • Keywords
    cardiology; medical image processing; single photon emission computed tomography; 3D Hann filter; cardiac lesion detectability; channelized Hotelling observer; dual-head 180-degree myocardial perfusion SPECT scans; imaging protocol; lesion detectability; myocardial perfusion; voxelized 4D cardiac-torso phantoms; Attenuation; Biomedical engineering; Humans; Image reconstruction; Imaging phantoms; Lesions; Myocardium; Protocols; Radiology; Telephony;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009267
  • Filename
    1009267