• DocumentCode
    1719779
  • Title

    Performance analysis of RAIDS disk arrays with a vacationing server model for rebuild mode operation

  • Author

    Thomasian, A. ; Menon, Jai

  • Author_Institution
    IBM Almaden Res. Center, San Jose, CA, USA
  • fYear
    1994
  • Firstpage
    111
  • Lastpage
    119
  • Abstract
    We analyze the performance of RAIDS disk arrays in normal, degraded, and rebuild modes. The analysis, which is shown to be highly accurate through validation against simulation results, achieves its accuracy by (1) modeling detailed disk characteristics; (2) developing a simple approximation to compute the mean response time for fork-join requests arising in degraded mode operation; and (3) using a vacationing server model with multiple vacation types for rebuild mode analysis. According to this model vacations (rebuild reads) are started when the server (disk) becomes idle and are repeated until the arrival of an external disk request. Type one (two) vacations correspond to the reading of the first track which requires a seek (successive tracks requiring no seeks). The analytic solution is used to quantify the effect of different rebuild options, such as read redirection and the split-seek option
  • Keywords
    magnetic disc storage; storage management; RAIDS disk arrays; fork-join requests; mean response time; performance analysis; rebuild mode operation; redundant arrays of inexpensive disks; vacationing server model; Analytical models; Availability; Bandwidth; Computational modeling; Degradation; Delay; IEEE news; Neck; Performance analysis; Writing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Data Engineering, 1994. Proceedings.10th International Conference
  • Conference_Location
    Houston, TX
  • Print_ISBN
    0-8186-5402-3
  • Type

    conf

  • DOI
    10.1109/ICDE.1994.282999
  • Filename
    282999