  • Title

    Fast polycrystalline-CdTe detectors for LHC luminosity measurements

  • Author

    Rossa, E. ; Gschwendtner, E. ; Placidi, M. ; Schmickler, H. ; Brambilla, A. ; Mongellaz, F. ; Verger, L. ; Cindro, V. ; Mikuz, M. ; Moritz, P.

  • Author_Institution
    CERN, Geneva, Switzerland
  • Volume
    4
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    2439
  • Lastpage
    2442
  • Abstract
    Beam diagnostics in future high-energy accelerators will require long lived instrumentation in highly hostile radiation environments. A research program aiming at individuating new solutions and testing them under extreme operational conditions has been launched at CERN in the framework of developments for LHC instrumentation. Its outcome might be used in future accelerator projects, in industry or in physics applications. The detectors which will be adopted for the LHC luminosity monitoring and optimization will be installed close to or inside copper absorbers specifically designed for radiation protection of the accelerator magnetic elements in the interaction regions. These detectors will have to withstand extreme radiation levels and their long-term operation has to be assured without requiring human intervention. Polycrystalline-CdTe detectors have demonstrated their radiation hardness against extreme doses of X-ray exposure in the LEP collider and are considered as good candidates for LHC luminosity monitoring applications. After recalling a series of measurements obtained on CdTe samples exposed to different sources to study their time response and sensitivity we present results on their performance after irradiation at doses of 1016 neutrons/cm2. This is a preliminary step in the program intended to test the samples during and after irradiation up to levels of 1018 neutrons/cm 2 and 1016 protons/cm2 comparable to those anticipated at the detector locations over ten years of operation of the accelerator
  • Keywords
    neutron effects; particle beam diagnostics; proton effects; semiconductor counters; CdTe; CdTe detectors; LHC; beam diagnostics; luminosity measurement; neutron irradiation; polycrystalline-CdTe detectors; proton irradiation; radiation hardness; Copper; Design optimization; Instruments; Large Hadron Collider; Neutrons; Particle beams; Physics; Radiation detectors; Radiation monitoring; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009312
  • Filename