DocumentCode
1720666
Title
Research on Calibration Method of Magnetic Sensor in Hybrid-Source Magneto Tellurics
Author
Yanzhang, Wang ; Defu, Cheng ; Yunxia, Wan ; Jun, Lin
fYear
2007
Firstpage
28126
Lastpage
29221
Abstract
To obtain sensor sensitivity to the real weak magnetic field intensity in field so that it can be used in hybrid-source magneto tellurics, a kind of indoor calibration method of magnetic sensor is introduced. In this paper, with calibration conditions being satisfied, a calibration system was designed and results error was analysed. Because of the power-line disturbance, magnetic shielding and its influence to the calibrating precision are introduced.
Keywords
calibration; magnetic sensors; magnetic shielding; calibration method; hybrid-source magneto tellurics; magnetic sensor; magnetic shielding; mutual inductance; power-line disturbance; weak magnetic field intensity sensitivity; Calibration; Frequency; Geology; Instruments; Magnetic analysis; Magnetic sensors; Magnetic shielding; Saturation magnetization; Solenoids; Voltage; Magnetic shielding; Mutual inductance; Sensor calibration; Sensor sensitivity;