• DocumentCode
    1721339
  • Title

    MEMS sensor for detecting mercury at ppb levels

  • Author

    Scaggs, J. ; Russell, D.D. ; Hill, M.W. ; Duttagupta, S.P.

  • Author_Institution
    Dept. of Chem., Boise State Univ., ID, USA
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    162
  • Abstract
    Summary form only given. Sub-surface science research is necessary to assist the Department of Energy (DOE) in solving complex environmental problems associated with hazardous contaminants in soil and groundwater at DOE sites. These contaminants include hazardous metals such as mercury. A novel mercury ion selective electrode has been constructed to have a strongly coordinating macrocyclic ligand binding site covalently attached to a polythiophene film using 1-1,4,10-trioxa-7,13-diazacyclopentadecane-1-thiophenylmethane (TDCD-thiophenylmethane) as a specific chelator. In amperometric mode, the current is proportional to mercury (II) concentrations down to 2 ppb. Reversible cyclic voltammetric waves show that both mercury (I) and mercury (II) are stabilized by the ligand. Monomethyl mercury and vapor phase elemental mercury are also electrochemically determined. Dissolved oxygen and heavy metal cations show no significant interference, even at ten times the Hg concentration. The polymer surface shows robust performance for two years or longer. Fabrication strategies are being developed to optimize probe performance. Variables under study include substrate surface roughness, the ratio of derivatized thiophene (TDCD-thiophenylmethane) to underivatized thiophene in the surface polymer, ratio of thiophene with two chelating rings to thiophene with only one, number and thickness of electrodeposited polymer layers, composition of polymer layers, and number of -CH2- units separating the chelating ring from the thiophene monomer units. The probe exhibits linear response to Hg concentration, and detects Hg in several forms
  • Keywords
    electrochemical sensors; groundwater; mercury (metal); microsensors; optimisation; pollution measurement; soil; surface topography; 1-1,4,10-trioxa-7,13-diazacyclopentadecane-1-thiophenylmethane chelator; Hg; Hg concentration; Hg detection; MEMS sensor; TDCD-thiophenylmethane chelator; amperometric mode; chelating rings; contaminants; coordinating macrocyclic ligand binding site; covalent attachment; derivatized thiophene; dissolved oxygen; electrochemical determination; electrodeposited polymer layers; environmental problems; fabrication strategies; groundwater contamination; hazardous contaminants; hazardous metals; heavy metal cations; ligand; linear Hg concentration response; mercury; mercury (I) stabilization; mercury (II) concentrations; mercury (II) stabilization; mercury detection; mercury ion selective electrode; monomethyl mercury; optimized probe performance; polymer layer composition; polymer surface; polythiophene film; reversible cyclic voltammetric waves; soil contamination; sub-surface science research; substrate surface roughness; surface polymer; thiophene monomer units; underivatized thiophene; vapor phase elemental mercury; Electrodes; Environmental factors; Mercury (metals); Micromechanical devices; Polymers; Probes; Rough surfaces; Soil; Surface roughness; US Department of Energy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    University/Government/Industry Microelectronics Symposium, 2001. Proceedings of the Fourteenth Biennial
  • Conference_Location
    Richmond, VA
  • ISSN
    0749-6877
  • Print_ISBN
    0-7803-6691-3
  • Type

    conf

  • DOI
    10.1109/UGIM.2001.960321
  • Filename
    960321