  • Abstract
    Integrated large-scale multivariable control and closed-loop real-time optimization was implemented on the power plant at Mitsubishi chemical (Mizushima) plant. The multivariable control system controls 3 boilers and 5 turbines simultaneously. The control system also controls the site-wide steam header pressure. The real-time optimization system is composed of a power plant model and ethylene plant steam turbine model, and the number of model´s equations is about 10,000. The real-time optimization system optimizes turbine load in the power plant and the site-wide steam balance with about 10 minutes frequency. Most efficient operation of the power plant is realized by the integrated system
  • Keywords
    boilers; closed loop systems; distributed control; large-scale systems; multivariable control systems; optimisation; power plants; predictive control; pressure control; real-time systems; steam turbines; Mitsubishi chemical plant; boilers; closed-loop systems; distributed control; dynamic matrix control; ethylene plant; large-scale systems; multivariable control; optimization; power plant; predictive control; pressure control; real-time systems; steam turbines; Boilers; Chemicals; Control systems; Equations; Large scale integration; Power generation; Power system modeling; Pressure control; Real time systems; Turbines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Applications, 1998. Proceedings of the 1998 IEEE International Conference on
  • Conference_Location
    Trieste
  • Print_ISBN
    0-7803-4104-X
  • Type

    conf

  • DOI
    10.1109/CCA.1998.721684
  • Filename
    721684