DocumentCode
1724515
Title
Flashover path of charged spacer surfaces in compressed gases
Author
Theophilus, G.D. ; Shungyuan Li ; Srivastava, K.D.
Author_Institution
British Columbia Univ., Vancouver, BC, Canada
fYear
1992
Firstpage
448
Lastpage
453
Abstract
While investigating the effects of accumulation of charges on insulating surfaces in gas-insulated apparatus, it was observed that the flashover paths deviated from the surface of the spacer. In the present work, it is shown that the observed paths are consistent with the computed electric field patterns in the presence of charges on the spacer surfaces. The results reported were obtained with hemispherically capped rod electrodes of diameters varying between 3.2 mm and 10 mm and cylindrical spacers of 40-mm diameter and 30-mm height subjected to lightning impulses. Surface charges were measured in situ using electrostatic probes
Keywords
electric fields; flashover; gaseous insulation; surface discharges; charged spacer surfaces; compressed gases; computed electric field patterns; electrostatic probes; flashover paths; gas-insulated apparatus; hemispherically capped rod electrodes; lightning impulses; Computational modeling; Corona; Current measurement; Electrodes; Electrostatic measurements; Flashover; Gas insulation; Gases; Lightning; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1992. Annual Report. Conference on
Conference_Location
Victoria, BC
Print_ISBN
0-7803-0565-5
Type
conf
DOI
10.1109/CEIDP.1992.283211
Filename
283211