DocumentCode :
1729076
Title :
Experimental setup for very high resolution animal PET based on solid state detector
Author :
Park, S. ; Han, L. ; Wilderman, S.J. ; Sukovic, P. ; Czermak, A. ; Jalocha, P. ; Sowicki, B. ; Kowal, M. ; Dulinski, W. ; Maehlum, G. ; Nygard, E. ; Yoshioka, K. ; Fuster, J. ; Lacasta, C. ; Mikuz, M. ; Roe, S. ; Weilharnmer, J. ; Meier, D. ; Rogers, W.L.
Author_Institution :
Coll. of Eng., Michigan Univ., Ann Arbor, MI, USA
Volume :
2
fYear :
2001
Firstpage :
1120
Abstract :
A very high resolution animal PET instrument was investigated using Monte Carlo simulations. The instrument consists of an outer cylindrical BGO scintillation detector surrounding an inner cylindrical solid state detector composed of 0.3 mm square silicon pads. The interaction point of gamma rays that scatter in the pad detector can be accurately localized in 3D to within the pad volume. Total energy is known from the summed energy in silicon and BGO detectors. Simulation results show 192 μm spatial resolution for events in which both annihilation photons scatter in silicon detectors. We have constructed a prototype Compton PET instrument using two silicon detectors with 1.4 mm square pads, two CCDAQ data acquisition units that have digital signal processors, a source turntable, and a coincidence unit. Using this experimental setup the energy spectrum of photons from technetium (Tc-99m) was acquired with 2.45 keV energy resolution and the timing spectrum of annihilation photons from fluorine (F-18) was obtained with 1.9 ns timing resolution. This experimental, setup will be used to verify the simulation results for the high resolution PET that is expected to have a maximum resolution of 0.7 mm FWHM at the center of the field of view.
Keywords :
Monte Carlo methods; data acquisition; positron emission tomography; silicon radiation detectors; solid scintillation detectors; Be2GeO5; CCDAQ data acquisition units; Monte Carlo simulations; Si; annihilation photons; coincidence unit; digital signal processors; gamma rays; inner cylindrical solid state detector; interaction point; outer cylindrical BGO scintillation detector; prototype Compton PET instrument; silicon pads; solid state detector; source turntable; very high resolution animal PET; Animals; Electromagnetic scattering; Energy resolution; Instruments; Particle scattering; Positron emission tomography; Silicon; Solid scintillation detectors; Solid state circuits; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2001 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-7324-3
Type :
conf
DOI :
10.1109/NSSMIC.2001.1009747
Filename :
1009747