• DocumentCode
    1730769
  • Title

    Fabric sensors for the measurement of physiological parameters

  • Author

    Catrysse, M. ; Puers, R. ; Hertleer, C. ; Van Langenhove, L. ; van Egmond, H. ; Matthys, D.

  • Author_Institution
    ESAT-MICAS, K.U. Leuven, Leuven, Belgium
  • Volume
    2
  • fYear
    2003
  • Firstpage
    1758
  • Abstract
    In this paper, we present fabric sensors for the recording of electrocardiogram (ECG) and respiration rate. Special attention is given to the dedicated sensor interface circuits. The sensors are integrated in a prototype belt for an intelligent suit. The suit will contain not only the sensors, but also the interface, data handling, storage and transmission circuitry. The suit is intended for the monitoring of children in a hospital environment.
  • Keywords
    biosensors; electrocardiography; intelligent sensors; prototypes; ECG; data handling; data storage; electrocardiogram; fabric sensors; hospital environment; intelligent suit; prototype belt; respiration rate; sensor interface circuits; transmission circuitry; Circuit noise; Electrocardiography; Electrodes; Fabrics; Impedance; Instruments; Intelligent sensors; Low-frequency noise; Signal to noise ratio; Textiles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th International Conference on, 2003
  • Conference_Location
    Boston, MA, USA
  • Print_ISBN
    0-7803-7731-1
  • Type

    conf

  • DOI
    10.1109/SENSOR.2003.1217126
  • Filename
    1217126