• DocumentCode
    1731429
  • Title

    Humidity measurement by dynamic dew-point detection

  • Author

    Lang, W. ; Glosch, H. ; Billat, S. ; Querrioux, T. ; Kunze, M. ; Ashauer, M. ; Sandmaier, H.

  • Author_Institution
    HSG-IMIT, Schwenningen, Germany
  • Volume
    2
  • fYear
    2003
  • Firstpage
    1864
  • Abstract
    A new humidity measurement method is described. A thin membrane is cooled below the dew point temperature. Then it is rapidly heated. The heating curve (temperature versus time) gives the dew point and the amount of adsorbed water. The method is especially useful for the range of very high humidity, where most other methods are difficult to apply.
  • Keywords
    heat treatment; humidity measurement; membranes; temperature sensors; adsorbed water; dew point temperature; dynamic dew-point detection; heating curve; humidity measurement; thin membrane; Biomembranes; Equations; Heat transfer; Humidity measurement; Process control; Soil measurements; Temperature sensors; Thermal conductivity; Vehicle dynamics; Water heating;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th International Conference on, 2003
  • Conference_Location
    Boston, MA, USA
  • Print_ISBN
    0-7803-7731-1
  • Type

    conf

  • DOI
    10.1109/SENSOR.2003.1217152
  • Filename