DocumentCode :
1732478
Title :
Flow disturbance rejection of pneumatic vibration isolators using compensation input
Author :
Nakamura, Yukinori ; Fukuda, Ryo ; Wakui, Shinji
Author_Institution :
Inst. of Eng., Tokyo Univ. of Agric. & Technol., Koganei, Japan
fYear :
2012
Firstpage :
247
Lastpage :
252
Abstract :
This paper considers the compensation of flow disturbance to the pneumatic vibration isolators. In our method, the disturbance is estimated by observer without feedback of the estimate. Then, by using simple moving average, time series data of the estimated disturbance is smoothed to reduce the noise of a position sensor. Finally, the shaped signal is added in the control system of the isolators for suppression of the flow disturbance. Experimental results show that the compensation input improves the performance of vibration control.
Keywords :
compensation; observers; pneumatic control equipment; position control; time series; vibration isolation; compensation input; control system; disturbance estimation; flow disturbance rejection; noise reduction; observer; pneumatic vibration isolators; position sensor; shaped signal; time series data; vibration control; Isolators; Noise; Servomotors; Springs; Valves; Vibrations;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advanced Mechatronic Systems (ICAMechS), 2012 International Conference on
Conference_Location :
Tokyo
ISSN :
1756-8412
Print_ISBN :
978-1-4673-1962-1
Type :
conf
Filename :
6329718
Link To Document :
بازگشت