• DocumentCode
    1732823
  • Title

    Analysis of internal PD pulses accompanying with electrical tree in LDPE

  • Author

    Kang, S.H. ; Park, Y.G. ; Shin, T. ; Lim, K.J. ; Zahn, M.

  • Author_Institution
    High Voltage Lab., Chung-Buk Nat. Univ., Cheongju, South Korea
  • Volume
    1
  • fYear
    1998
  • Firstpage
    126
  • Abstract
    The correlation between propagation of electrical tree and internal partial discharges is discussed. We used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscopy and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the case of branch type tree, the length of the tree had a good linear relation with average discharge power of PD pulses. On the other hand, in the case of bush type tree, the area of the tree had a good linear relation with the average discharge power of PD pulses
  • Keywords
    partial discharges; polyethylene insulation; trees (electrical); LDPE; average discharge power; branch type tree; bush type tree; insulation life; internal PD pulses; linear relation; needle-plane electrode system; needle-shaped void; optical microscopy; propagation of electrical tree; tree area; tree length; Application software; Electrodes; Needles; Optical microscopy; Optical propagation; Optical pulses; Partial discharges; Surface discharges; Trees - insulation; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1998. Conference Record of the 1998 IEEE International Symposium on
  • Conference_Location
    Arlington, VA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-4927-X
  • Type

    conf

  • DOI
    10.1109/ELINSL.1998.704679
  • Filename