DocumentCode
1734876
Title
Extracting vectors from application traces for power integrity analysis
Author
Olsson, Martin ; Pihl, Johnny ; Andersson, Daniel ; Larsson-Edefors, Per
Author_Institution
Atmel Norway AS, Tiller, Norway
fYear
2011
Firstpage
39
Lastpage
42
Abstract
We present an approach to power integrity analysis that is based on traces resulting from application execution. The first phase of the approach identifies a vector that maximally stresses the power grid, while the second phase entails simulation of the selected vector on an accurate grid model. We show, for an AVR32 32-bit microcontroller, that the vector we identify gives rise to a supply voltage drop that is 18% larger than that of the vector obtained in a regular flow, which considers average power dissipation per cycle.
Keywords
electric potential; integrated circuit interconnections; integrated circuit modelling; microcontrollers; AVR32 32-bit microcontroller; grid model; power dissipation; power grid; power integrity analysis; simulation; supply voltage drop; vector; word length 32 bit;