Abstract :
Fans in deep level mines consume significant amounts of energy, usually between 1 and 4MWe per fan. When these are overdesigned, as is often the case, energy is wasted and an opportunity exists for energy efficiency interventions. Typically, savings of 1MWe in a three-fan configuration can be achieved. This paper presents the theoretical viability of the replacement of main fan station impellers to ensure more efficient fan operation. The new impellers will be designed to be more aerodynamically efficient and reduce the shaft load on the motor at the current operating point. The result is reduced electrical energy consumption and a reduction in the electrical costs of the fan station. Impeller replacements are feasible on mines where fans operate below their design point. The majority of underground gold mines were designed for a larger pressure drop and lower volume flow than is presently being encountered. This paper will focus on the challenges that are faced in order to arrive at a suitable impeller with improved efficiency. The aim is to design an impeller with lower pressure head and higher volume flow capability, shifting the best efficiency point to a slightly higher volume flow. This requires the manipulation of impeller design parameters such as blade width, blade tip exit angle, impeller outer and eye diameter and blade number. Various parameters that influence the choke and surge margins, such as the use of splitter vanes and inlet eye shape; were also identified.
Keywords :
aerodynamics; energy conservation; fans; gold; impellers; mining industry; power consumption; pumping plants; South African gold mining industry; aerodynamic; blade number; blade tip; blade width; choke; deep level mines; electrical cost reduction; electrical energy consumption; energy efficiency; eye diameter; fan stations; impeller design parameters; impeller replacements; inlet eye shape; power 1 MW to 4 MW; power savings; pressure drop; shaft load; splitter vanes; surge margins; three-fan configuration; underground gold mines; volume flow; Aerodynamics; Blades; Electric shock; Fans; Friction; Impellers; Shafts;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial and Commercial Use of Energy Conference (ICUE), 2012 Proceedings of the 9th
Conference_Location :
Stellenbosch
ISSN :
2166-0581
Print_ISBN :
978-1-4673-1241-7
Type :
conf
Filename :
6330151
Link To Document :
بازگشت