Onset voltage of corona in SF6-N2 mixtures
Author
El-Bahy, M.M.
Author_Institution
Dept. of Electr. Eng., Fac. of Eng. at Shubra, Cairo, Egypt
Volume
1
fYear
2000
fDate
2000
Firstpage
393
Abstract
The onset voltages of positive and negative coronas are theoretically predicted for SF6-N2 mixtures. For positive onset, the method of calculation is based on the condition necessary for the onset streamer to propagate. For negative onset, the method of calculation is based on the criterion developed for the formation of repetitive negative corona pulses. The analysis is applied for rod-plane and sphere-sphere gaps. The calculated onset voltages obtained in both positive and negative coronas agree well with those measured values within ±10%
Keywords
SF6 insulation; corona; electric strength; gas mixtures; nitrogen; N2; SF6; SF6-N2; breakdown voltages; corona onset voltages; gas mixtures; negative corona; onset streamer propagation condition; positive corona; repetitive pulses formation; rod-plane gaps; sphere-sphere gaps; Absorption; Anodes; Corona; Electron emission; Electron mobility; Head; Ionization; Space charge; Sulfur hexafluoride; Voltage;